Product Show

Location \ HomeProductsOutdoor High Voltage Isolation Load Switch

High Voltage Load Break Switch

  • Product Details
  • Online Enquiry

High voltage load switch. FZW13A-12

High voltage, Load switch, 12kv

High voltage load switch FZW13A-12 Generally equipped with a simple arc extinguishing device, the working process is: when the gate is divided, under the action of the gate spring, the main axis rotates clockwise. On the one hand, the piston moves upwards through the crank slider mechanism to compress the gas; On the other hand, through the transmission system composed of two sets of four-pole mechanisms, the main gate knife is opened first, and then the arc brake knife is pushed to open the arc contact, and the compressed air in the cylinder blows out the arc through the nozzle. When closing, through the main shaft and transmission system, the main gate knife and the arc brake knife rotate clockwise at the same time, and the arc contact is closed first; The main axis continues to rotate so that the main contact is subsequently closed. In the closing process, the separation spring simultaneously stores energy. Because the load switch can not switch off the short-circuit current, it is often used in combination with the flow-limiting high-pressure fuse. Using the flow-limiting fuse's flow-limiting function, it not only completes the task of the cut-off circuit, but also can significantly reduce the heat caused by the short-circuit current.


The use of environmental conditions

1. Ambient air temperature +40℃ ~ -30℃;

2. Elevation no more than 3000 meters;

3. Wind pressure shall not exceed 700Pa (equivalent to wind speed of 34m/s);

4. Pollution level does not exceed Ⅳ level;

5. Not often violent vibration, earthquake intensity does not exceed 8 degrees.


Technical Data

Number

Description

Unit

Data

1

Rated voltage

kV

12

2

Rated
Insulation
Level


I min Power frequency withstand voltage

Dry test

kV

42

Wet test

34

Lighting implus withstand voltage(peak)

75

3

Rated Frequency

Hz

50

4

Rated current

A

630

5

Rated Active load breaking current

A

630

6

Rated cable charging breaking current

A

10

7

Rated short time withstand current

kA

20

8

Rated Peak withstand current

kA

50

9

Rated short-circuit closing current

kA

50

10

Rated short circuit duration

S

4

11

Rated breaking capacity of no-load transformer

KVA

1250

12

Rated operation sequence


C-0

13

Mechanical Life

time

10000


Outline of FZW13A-12

1

2

Installation Dimension

3

Welcome to our website! Please send your words at any time in the following form and ask us, we will contact you and provide you with the corresponding service as soon as possible.

  • Title:

    *
  • Name:

    *
  • Email:

    *
  • Tel:

  • WhatsApp:

  • Address:

Message

  • Verification code:

    *